Overview:
The BIT-100 provides limit comparison and absolute value
testing of up to 64 PCM parameters. It also provides 10
output bits for transmitter setup. Testing includes two’s
compliment data. The failure of any parameter can be
monitored at any or all of the 8 programmable Flag outputs.
Flags 1-4 are also driven out using Opto-Isolators. Each
parameter result is uniquely identified in a 64-bit error
register. This error register is translated into Error Status
Words that can inserted into the PCM. At 16 BPW, the
results of all 64 parameters can be read in 4 reads (4x16 =
64 parameters). Extended Reads are provided when operating
at less than 16 BPW.
Download Product Brief (PDF)